Model:LOX100A

One press measurement

Small and portable

OLED color screen

Non-invasive testing

Taiwan Chip

8 seconds automatic shutdown

  • Product introduction
  • Operational knowledge

指夹式脉搏血氧仪

指夹式脉搏血氧仪

指夹式脉搏血氧仪

指夹式脉搏血氧仪

指夹式脉搏血氧仪

指夹式脉搏血氧仪

指夹式脉搏血氧仪

指夹式脉搏血氧仪

指夹式脉搏血氧仪

指夹式脉搏血氧仪


Blood oxygen level Pulse rateReach at a touch Lepu LOX100A Fingertip Pulse Oximeter
A device combines many advantagesOne press measurementSmall and portableOLED colour screenNon-invasive measurementTaiwan Chip8 seconds automatic shutdown
Leading enterprise in the domestic medical fieldHigh quality products are trustworthy
20th anniversaryFocus on medical care for 20 years
Leading domestic medical enterprise
Clinical medicine approvalProvide more than 60 million medical products
for the clinic
Famous in the medical industryCurrent market value of Lepu Medical is 80 billion
Authoritative certification Health guaranteeProducts have passed CE, ISO 13485, NMPA, FDA certifications
and multiple quality and health certification standards, and have export qualifications.
Using Taiwan chips
Ensure accurate measurement
High performance, high-quality chips and sensors, painless and noninvasive optical detection technology,
capture blood flow signals per second, high data accuracy.
Patented blood oxygen detection systemSatisfy the measurement of blood oxygen and pulse of people with different skin colors
Medical silicone padMore comfortable Measurement
Fall-proof design, reliable and assured for daily use After a 3-meter high drop test, the impact resistance is remarkable.
Two-way display for easy readingHumanized design, press the short power button to change the data display direction,
which is convenient for the family to read the data intuitively.
Blood oxygen saturation is an important indicator of disease diagnosisBlood oxygen saturation (SaO2) refers to the percentage of
the capacity of oxygenated hemoglobin bound by oxygen in human blood.
*In the 'New Coronavirus Pneumonia Diagnosis and Treatment Plan' jointly issued by the General Office of the National Health Commission and the Office of the State Administration of Traditional Chinese Medicine,
when the oxygen saturation is less than 93%, it is considered a critically ill patient and requires auxiliary respiratory therapy.
Effective management of chronic diseasesLepu LOX100A Fingertip Pulse Oximeters
Product Information
Production Name: Lepu LOX100A Fingertip Pulse OximetersWeight: 60gDimension: 69mm (L) * 35mm (W) * 29mm (H)Display mode: OLEDBlood oxygen saturation display range: 0%-99% Accuracy: 70%-100%±2%Pulse rate display range: 30bpm-250bpm Accuracy: ±2bpmBattery supply: 2 AAA batteriesPower consumption:<30mABattery life: 25 hours of continuous useWorking temperature: 5℃-40℃Note: Please read the product manual carefully or purchase and use under the guidance of medical staff
ATTENTIONSPlease read before use

1. This product cannot be used for continuous measurement.

2. Electrosurgical equipment and defibrillator will affect the use of this instrument.

3. It cannot be used together with MRI or CT equipment.

4. Do not squeeze the silicone pad with your fingers during use.

5. Before using the pulse oximeter, it must be ensured that the pulse oximeter is in normal working condition and operating environment.

6. Do not take the information displayed by the pulse oximeter as the only basis for clinical diagnosis. Pulse oximeter is only used as an auxiliary means in diagnosis. It must be used in conjunction with clinical manifestations and symptoms and the doctor's diagnosis.

7. The measured points need to be changed periodically for long-term use or according to different conditions of patients. The measured point must be changed every 4 hours at most, and the skin integrity and circulation condition of the patient must be checked, and the correct adjustment must be made.

8. Do not disinfect the pulse oximeter with high temperature, high pressure, gas fumigation or liquid immersion. Please clean and disinfect the pulse oximeter and its accessories according to the manufacturer's requirements. The external power supply must be disconnected before clearing or disinfecting the pulse oximeter.

9. The instrument meets the electromagnetic compatibility requirements of YY0505 electronic medical products or systems.

Radio transmission equipment or other electromagnetic interference in healthcare centers or other environments may affect the performance of the instrument.

10. Portable radio communication equipment may affect the performance of the instrument.

11. This instrument should not be close to or stacked with other equipment.

12. This instrument is not recommended for patients during transportation. For example, the patient is in an ambulance.

13. Do not disassemble, install or repair the equipment without authorization.

14. When contacting with human body, the temperature shall not exceed 41℃. The recommended maximum usage time of single boot is 1~2 hours

15. This product can not be used for children less than 20kg, pregnant women and lactating women.

16. This device has no alarm function.

17. Do not exercise violently before measurement, otherwise the accuracy of measurement will be affected.

18. The nails of the measured person should not be too long, can not wear fake nails, and can not apply nail polish and other cosmetics to the fingers.